The presence of radiologically opaque breast implants (either saline or silicone) might interfere with the radiographic sensitivity of the mammograph, that is, the image might not show any tumor(s) present. In this case, an Eklund view mammogram is required to ascertain either the presence or the absence of a cancerous tumor, wherein the breast implant is manually displaced against the chest wall and the breast is pulled forward, so that the mammograph can visualize a greater volume of the internal tissues; nonetheless, approximately one-third of the breast tissue remains inadequately visualized, resulting in an increased incidence of mammograms with false-negative results.[102]

Furthermore, The Effect of Study design Biases on the Diagnostic Accuracy of Magnetic Resonance Imaging for Detecting Silicone Breast Implant Ruptures: a Meta-analysis (2011) reported that the breast-screening MRIs of asymptomatic women might overestimate the incidence of breast implant rupture.[53] In the event, the U.S. Food and Drug Administration emphasised that “breast implants are not lifetime devices. The longer a woman has silicone gel-filled breast implants, the more likely she is to experience complications.”[54]
Breast implants are not lifetime devices and breast implantation may not be a one-time surgery. The most common complications for breast augmentation and reconstruction with MemoryGel® Implants include any reoperation, capsular contracture, and implant removal with or without replacement. The most common complications with MemoryShape® Implants for breast augmentation include reoperation for any reason, implant removal with or without replacement, and ptosis. The most common complications with MemoryShape® Implants for breast reconstruction include reoperation for any reason, implant removal with or without replacement, and capsular contracture. A lower risk of complication is rupture. The health consequences of a ruptured silicone gel breast implant have not been fully established. MRI screenings are recommended three years after initial implant surgery and then every two years after to detect silent rupture. The most common complications with MENTOR® Saline-filled Implants include reoperation, implant removal, capsular contracture, breast pain, and implant deflation.

Manufacturer’s warranty programs can mitigate some of the costs of treating complications. But, the warranty payment is only available if a rupture is detected. Some surgeons fail to inform their patients of the need for periodic MRIs, or downplay the FDA recommendation in order to make a sale. “Many women don’t know about the maintenance costs and potential expenses of silicone gel implants,” reports Dr. Ellen Mahony, board-certified plastic surgeon in Westport, CT.  “Because rupture with a silicone gel implant is ‘silent,’ it can go undetected for an extended period, often not becoming obvious until the process of capsular contraction has begun.” Capsular contraction leads to a more complex surgery. That means added surgical costs which your warranty may not cover.
×